Rhein-Nadel Automation GmbH 5
VT-BA-ESR2000_EN_2023.docx
Please observe the following directives for intended use of the controllers:
The devices herein described must only be stored, fitted and operated under the conditions
specified in this documentation.
Here you are not concerned with domestic devices! They are solely intended to be used as com-
ponents for commercial or professional applications pursuant to EN 61000−3−2.
They satisfy the protection requirements of 2014/35/EU: Low Voltage Directive.
They do not constitute a machine as defined by 2006/42/EU: Machinery Directive.
A machine comprising the product must not be commissioned or put into operation for the in-
tended use until it has been declared to be in conformity with the EC Directive 2006/42/EU: Ma-
chinery Directive; Observe EN 60204−1.
Commissioning or starting operation for the intended use is only permitted in compliance with the
EMC Directive 2014/30/EU.
Use of the product in living areas may lead to EMC disturbance. The user is responsible for tak-
ing interference suppression measures.
They are optimised for operation of RNA bowl feeders and linear feeders. Observe the limits in-
dicated in the technical specification.
Attention!
Prior to start-up make sure that the protective earth conductor is connected and in proper
condition. Make the PE conductor test with approved test devices only.
Never start up despite detected damage.
Do not make any technical modifications to the device, except as described in this docu-
ment.
Never start up in an incompletely installed state.
Never operate the device without the required guards in place.
Connect, disconnect or change any electrical connections only in the absence of voltage.
Residual hazards may remain even if all directives have been observed and protective measures taken.
Such residual hazards must be considered by the user in the risk assessment of his machine/equipment.
Non-observance may lead to severe injury and damage to property!
Pay attention to the warning signs fitted to the device!
Symbol
Description
Hazardous voltage:
Prior to commencing any work on the product check for absence of voltage on all power con-
nections.
Leakage current:
Make fixed installation and PE connection according to EN 60204−1!
Attention
Before opening the controller, pull the mains plug and wait for the periods shown below, allowing
the DC link circuit capacitors to discharge down to a safe voltage level.
Discharge period: ESR 2000 5 minutes
Certain device parameter settings may cause overheating of the connected drive magnet, e.g., due to pro-
longed operation with an incorrect frequency setting.
2.4. Intended use
2.5. Residual hazards
2.5.1. Device
2.5.2. Protection of the drive system

Questions and Answers: