When a packet length between 1 and 1024 bytes is specified, data in the buffer
will be sent as soon it reaches the specified length.
Note: Data will also be sent as specified by the interval timeout or delimiter
settings even when data is not reaching the preset packet length.
When Delimiter 1 is enabled, the serial port will queue the data in the buffer
and send the data to the Cellular WAN/Ethernet WAN when a specific
character, entered in hex format, is received. A second delimiter character may
be enabled and specified in the Delimiter 2 field, so that both characters act as
the delimiter to control when data should be sent.
Delimiter1/2 (Hex)
@Transparent
Enter the delimiter in Hex.
Delimiter Process
@Transparent
The Delimiter process field determines how the data is handled when a
delimiter is received.
None: Data in the buffer will be transmitted when the delimiter is received; the
data also includes the delimiter characters.
Strip: Data in the buffer is first stripped of the delimiter before being
transmitted.
This item will show up When you enable any VPN tunnel of R3000, it means
serial data can be matched to this local IP address and be transmitted or
received via VPN tunnel.
Note: when you do not enable any VPN tunnel, this item will not show up.
Enter the Local port for Modbus.
Attached serial
device type
@Modbus
Select From “Modbus RTU slave”, “Modbus ASCⅡ slave”, “Modbus RTU
master” and “Modbus ASCⅡ master”.
Modbus RTU slave: router connects to Modbus slave device which works under
Modbus RTU protocol.
Modbus ASCⅡ slave: router connects to Modbus slave device which works
under Modbus ASCⅡprotocol.
Note: When select “Modbus RTU slave” and “Modbus ASC
Ⅱ
slave” protocol,
router is as TCP Server site, user need to enter a local port number in “Local Port
@Modbus” and wait to be connected.
Modbus RTU master: router connects to master device which works under
Modbus RTU protocol.
Modbus ASCⅡ master: router connects to master device which works under
Modbus ASCⅡ protocol.
Note: When select “Modbus RTU master” and “Modbus ASC
Ⅱ
master” protocol,
router is as TCP Client site, user need to enter slave address and slave port
number in “Slave Address @ Modbus Slave ” and “Slave Port @ Modbus Slave”,
and connect to Server site.
Add the Modbus slaves which will be polled by Modbus master (router). This
section only displayed when you select “Modbus RTU master” or “Modbus ASC
Ⅱ master” in “Attached serial device type”.