Roche Diagnostics April 2007
6 Service manual · Version 2.0
91xx pH/Electrolyte Analyzers
Service functions menu B-14
Calibration sequence B-15
7 Software operation 9120, 9130, 9140
Software operation 9120, 9130, 9140 B-19
Overview B-19
Overall program operating flow B-20
Main menu B-21
Measurement sequence B-22
Print functions menu B-23
QC/standard/urine sample menu B-24
Daily maintenance menu B-25
Operator functions menu B-26
Program instrument menu B-27
Service functions menu B-28
Calibration sequence B-29
8 Software operation 9180
Software operation 9180 B-33
Overview B-33
Overall program operation flow B-34
Main menu B-35
Measurement sequence B-36
Print functions menu B-37
QC/standard/dialysate/urine sample menu B-38
Daily maintenance menu B-39
Operator functions menu B-40
Program instrument menu B-41
Service functions menu B-42
Calibration sequence (1) (Example Na/K/Li
calibration) B-43
Calibration sequence (2) (Example Na/K/Li
calibration) B-44
Power-up B-45
9 Software operation 9181
Software operation 9181 B-49
Overview B-49
Overall program operting flow B-50
Main menu B-51
Manual measurement sequence B-52
Automated measurement sequence B-53
Print functions menu B-54
QC/std/dialysate/urine sample menu B-55
Daily maintenance menu B-56
Operator functions menu B-57
Program instrument menu B-58
Service functions menu B-59
Calibration sequence (1) (example Na/K/Li
calibration) B-60
Calibration sequence (2) (example Na/K/Li
calibration) B-61
Power-up sequence B-62
10 Service functions
Service functions B-65
TEST ELECTRODES B-65
TEST SAMPLE SENSOR B-65
TEST SnapPak SENSOR (9180 and 9181 only) B-65
TEST LANGUAGE SWITCH (9180 and 9181 only)
B-65
TEST SAMPLE DOOR (except 9181) B-66
TEST PROBE (9181 only) B-66
TEST AUTOSAMPLER (9181 only) B-66
TEST PUMP B-66
TEST PINCH VALVES B-67
TEST INTERFACE B-67
TEST AMPLIFIER B-67
ENTER SERVICE CODE B-67
Miscellaneous functions B-69
Maintenance Part C
11 Adjustments
Adjustments C-5
Sample contacts adjustment (9110 only) C-5
Sample sensor adjustment (9120/9130/9140/9180/
9181 only) C-5
Temperature Adjustment (9110/9140/9180/9181
only) C-6
12 Maintenance
Maintenance C-9
Daily maintenance C-9
Weekly maintenance C-9
Monthly maintenance C-9
Six month maintenance C-9
Annual preventive maintenance C-9
Troubleshooting Part D
13 Troubleshooting
Error messages and troubleshooting D-5
Status-LEDs D-5
STATUS: NOT CALIBRATED D-5
STANDARD A NOT DETECTED D-5
STANDARD B NOT DETECTED, STANDARD C
NOT DETECTED (9180/9181 only) D-6
CHECK SAMPLE CONTACTS(9110), CHECK
SAMPLE SENSOR (9120/30/40/80/81) D-6
CHECK REFERENCE HOUSING D-7
PLEASE CLOSE SAMPLE DOOR (except 9181) D-7
NO SAMPLE D-8
CLEANING FLUID NOT DETECTED D-8
CONDITIONING FLUID NOT DETECTED (except
9110) D-8
INTERFACE ERROR D-9