Rockwell Automation Publication 20D-PM001D-EN-P - March 2019 97
Programming and Parameters Chapter 2
590 RsTempCoefAdjust
The value specified in this parameter adjusts the temperature compensation coefficient which is calculated
based on the Slip regulator output. A value of 4096 in this parameter doubles the compensation coefficient.
Notes: This value should not be changed. This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
591 RsTmpCoefAdjstEn
A value of “1” in this parameter enables the temperature compensation function in flux and torque estimate
calculation, where the temperature information is based on the Slip regulator output. A value of “0” in this
parameter disables the temperature compensation function.
Notes: This value should not be changed. This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
592 VqsReg On Hystr
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
593 SlipReg On Hystr
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
-/+32767
RW 16-bit
Integer
594 Nth Torq Compen
Defines harmonic frequency as <n> times mechanical frequency.
Note: This parameter was added for firmware version 5.002.
Default:
Min/Max:
0
0/1000
RW 16-bit
Integer
595 Nth Amplitude
Defines the compensation current amplitude for the Nth harmonic component.
Note: This parameter was added for firmware version 5.002.
Default:
Min/Max:
Scaling:
0
0/4096
4096/Par 2 [Motor NP FLA]
RW 16-bit
Integer
596 Nth Phase Shift
Defines the phase shift for the Nth harmonic component.
Note: This parameter was added for firmware version 5.002.
Default:
Min/Max:
Scaling:
0
-/+16384
16384/360 deg
RW 16-bit
Integer
597 Mth Torq Compen
Defines harmonic frequency as <m> times mechanical frequency.
Note: This parameter was added for firmware version 5.002.
Default:
Min/Max:
0
0/1000
RW 16-bit
Integer
598 Mth Amplitude
Defines the compensation current amplitude for the Mth harmonic component.
Note: This parameter was added for firmware version 5.002.
Default:
Min/Max:
Scaling:
0
0/4096
4096/Par 2 [Motor NP FLA]
RW 16-bit
Integer
599 Mth Phase Shift
Defines the phase shift for the Mth harmonic component.
Note: This parameter was added for firmware version 5.002.
Default:
Min/Max:
Scaling:
0
-/+16384
16384/360 deg
RW 16-bit
Integer
600 Lgx Comm Format
Indicates the Controller to Drive communication format.
Note: Option values 1…15 and 20…31 are “Reserved”
Default:
Options:
16 =
0 =
16 =
17 =
“Speed Ctrl”
“Not Used” 18 = “UserDefin 1”
“Speed Ctrl” 19 = “Motion”
“PositionCtrl” 32 = “CustmUserDef
601 From DL DataType
Sets the type of data for each word communicated from DriveLogix™ to the PowerFlex 700S drive. Setting a bit High will configure the associated word as a Real data type and setting the bit Low will
configure it for Integer data type.
602
to
622
FromDriveLogix00
to
FromDriveLogix20
These parameters display the input values communicated from the DriveLogix controller to the PowerFlex 700S
drive.
Default:
Min/Max:
0
-/+32 (dependant on Par 601 [From DL
DataType])
RO 32-bit
Integer
625 To DL DataType
Sets the data type for each word communicated from the PowerFlex 700S drive to DriveLogix. Setting a bit High will configure the associated word as a Real data type and setting the bit Low will
configure it for Integer data type.
No. Name
Description
Values
Linkable
Read-Write
Data Type
A
A
A
A
A
A
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
DL 20 Real
DL 19 Real
DL 18 Real
DL 17 Real
DL 16 Real
DL 15 Real
DL 14 Real
DL 13 Real
DL 12 Real
DL 11 Real
DL 10 Real
DL 09 Real
DL 08 Real
DL 07 Real
DL 06 Real
DL 05 Real
DL 04 Real
DL 03 Real
DL 02 Real
DL 01 Real
DL 00 Real
Default xxxxxxxxxxx000000000000000000000
Bit 313029282726252423222120191817161514131211109 8 7 6 5 4 3 2 1 0
0 = False
1 = True
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
DL 20 Real
DL 19 Real
DL 18 Real
DL 17 Real
DL 16 Real
DL 15 Real
DL 14 Real
DL 13 Real
DL 12 Real
DL 11 Real
DL 10 Real
DL 09 Real
DL 08 Real
DL 07 Real
DL 06 Real
DL 05 Real
DL 04 Real
DL 03 Real
DL 02 Real
DL 01 Real
DL 00 Real
Default xxxxxxxxxxx000000000000000000000
Bit 313029282726252423222120191817161514131211109 8 7 6 5 4 3 2 1 0
0 = False
1 = True

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 700S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 700S and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 700S Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 700S
CategoryController
LanguageEnglish

Related product manuals