EasyManuals Logo

Rockwell Automation MMI-HT-C2198-D032 User Manual

Rockwell Automation MMI-HT-C2198-D032
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #207 background imageLoading...
Page #207 background image
Installation
Transport System Installation
QuickStick HT User Manual 207
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
9. Run the LVDC power cable to the next motor controller in the path, route the cable so
it is shielded from damage and can be easily accessed for service.
10. Repeat Step 9 for each motor controller in the power chain.
NOTE: It is not necessary to connect all motors on a path to the same power supply
or to connect a power supply to only one path.
11. Bundle and dress all power cables (use nylon cable-ties) as required to keep all cable
routing clean.
12. Make sure that all NC LITE node controllers are mounted to grounded surfaces.
13. Make sure that the Ground stud on all NC-12 node controllers is connected to GND
(PE).
14. Make sure that all NC-E and NC-S node controllers are grounded through the chassis
ground connection in their power connectors.
15. See Facilities Connections on page 214 for external power connections.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MMI-HT-C2198-D032 and is the answer not in the manual?

Rockwell Automation MMI-HT-C2198-D032 Specifications

General IconGeneral
BrandRockwell Automation
ModelMMI-HT-C2198-D032
CategoryAccessories
LanguageEnglish

Related product manuals