CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MINimum:ABOVe.............................947
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MINimum:BELow............................. 947
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MINimum:NEXT...............................947
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MINimum[:PEAK].............................947
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:FRAMe <Frame> | <Time>
This command positions a marker on a particular frame.
Parameters:
<Frame> Selects a frame directly by the frame number. Valid if the time
stamp is off.
The range depends on the history depth.
<Time> Selects a frame via its time stamp. Valid if the time stamp is on.
The number is the (negative) distance to frame 0 in seconds.
The range depends on the history depth.
Example:
CALC:MARK:SGR:FRAM -20
Sets the marker on the 20th frame before the present.
CALC:MARK2:SGR:FRAM -2s
Sets second marker on the frame 2 seconds ago.
Manual operation: See "Frame (Spectrogram only)" on page 495
CALCulate<n>:MARKer:SGRam|SPECtrogram:SARea <SearchArea>
This command defines the marker search area for all markers.
Parameters:
<SearchArea> VISible
Performs a search within the visible frames.
Note that the command does not work if the spectrogram is not
visible for any reason (e.g. if the display update is off).
MEMory
Performs a search within all frames in the memory.
*RST: VISible
Manual operation: See "Marker Search Area" on page 504
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:XY:MAXimum[:PEAK]
This command moves a marker to the highest level of the spectrogram.
Usage:
Event
Manual operation: See "Marker Search Type" on page 503
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:XY:MINimum[:PEAK]
This command moves a marker to the minimum level of the spectrogram.
Usage:
Event
Analyzing Measurements (Basics)