CALCulate:LIMit<k>:LOWer:SPACing.............................................................................. 981
CALCulate:LIMit<k>:LOWer:STATe................................................................................. 981
CALCulate:LIMit<k>:LOWer:THReshold...........................................................................981
CALCulate:LIMit<k>:NAME.............................................................................................982
CALCulate:LIMit<k>:UNIT...............................................................................................982
CALCulate:LIMit<k>:UPPer[:DATA]................................................................................. 982
CALCulate:LIMit<k>:UPPer:MARGin................................................................................983
CALCulate:LIMit<k>:UPPer:MODE.................................................................................. 983
CALCulate:LIMit<k>:UPPer:OFFSet.................................................................................983
CALCulate:LIMit<k>:UPPer:SHIFt....................................................................................983
CALCulate:LIMit<k>:UPPer:SPACing...............................................................................984
CALCulate:LIMit<k>:UPPer:STATe..................................................................................984
CALCulate:LIMit<k>:UPPer:THReshold............................................................................984
CALCulate:LIMit:COMMent <Comment>
This command defines a comment for a limit line.
Parameters:
<Comment> String containing the description of the limit line. The comment
may have up to 40 characters.
Manual operation: See "Comment" on page 532
CALCulate:LIMit<k>:CONTrol[:DATA] <LimitLinePoints>
This command defines the horizontal definition points of a limit line.
Parameters:
<LimitLinePoints> Variable number of x-axis values.
Note that the number of horizontal values has to be the same as
the number of vertical values set with CALCulate:LIMit<k>:
LOWer[:DATA] or CALCulate:LIMit<k>:UPPer[:DATA]. If
not, the R&S FSW either adds missing values or ignores surplus
values.
The unit is Hz or s.
*RST: -
Usage: SCPI confirmed
Manual operation: See "Data points" on page 533
CALCulate:LIMit<k>:CONTrol:DOMain <SpanSetting>
This command selects the domain of the limit line.
Parameters:
<SpanSetting> FREQuency | TIME
*RST: FREQuency
Manual operation: See "X-Axis" on page 533