Remote Commands
R&S
®
FSW
984User Manual 1173.9411.02 ─ 19
Parameters:
<Distance> Defines the distance that the limit line moves.
The unit depends on CALCulate:LIMit<k>:UNIT
on page 982.
Usage: Event
Manual operation: See "Shift y" on page 534
CALCulate:LIMit<k>:UPPer:SPACing <InterpolType>
This command selects linear or logarithmic interpolation for the calculation of an upper
limit line from one horizontal point to the next.
Parameters:
<InterpolType> LINear | LOGarithmic
*RST: LIN
Manual operation: See "X-Axis" on page 533
See "Y-Axis" on page 533
CALCulate:LIMit<k>:UPPer:STATe <State>
This command turns an upper limit line on and off.
Before you can use the command, you have to select a limit line with CALCulate:
LIMit<k>:NAME on page 982.
Parameters:
<State> ON | OFF
*RST: OFF
Usage: SCPI confirmed
Manual operation: See "Visibility" on page 530
CALCulate:LIMit<k>:UPPer:THReshold <Limit>
This command defines an absolute limit for limit lines with a relative scale.
The R&S FSW uses the threshold for the limit check, if the limit line violates the thresh-
old.
Parameters:
<Limit> Numeric value.
The unit depends on CALCulate:LIMit<k>:UNIT
on page 982.
*RST: -200
Default unit: dBm
Manual operation: See "Threshold" on page 532
Analyzing Measurements (Basics)