Loading...
Getting started
R&S
®
TSME6
18User Manual 4900.0033.02 ─ 08
Recommendations/Limitations of modes
"Full auto-IP" mode
Only 1 PC and 1 or more R&S TSME6 devices per LAN interface, either con-
nected directly or via a L2 switch. (Do not use this mode when more than 1 PC
is physically connected to the same subnetwork, e.g. via the switch.)
The PC’s LAN interface must not receive an IP from a DHCP server. (The IP
address generated for PC must match the following pattern: 169.254.X.Y.)
Configure all R&S TSME6 devices on the same LAN interface with stored IP
addresses not in the range 169.254.1.0 – 169.254.254.255 (inclusive) to pre-
vent conflicts.
Note: R&S TSME6 devices with stored IP addresses in ranges 169.254.0.1 –
169.254.0.255 (inclusive) or 169.254.255.0 – 169.254.255.254 (inclusive) are
effectively operating in "partial auto-IP" mode.
Depending on the software accessing the R&S TSME6 devices, it is mandatory
to configure the stored IP addresses in all R&S TSME6 devices to be unique.
Example: R&S TSME Device Manager does not have this requirement,
ROMES / R&S NESTOR have such requirements depending on the use made
internally of the stored IP address as unique identifier.
"Partial auto-IP" mode
Use this mode only for specific cases. The preferred modes are "full auto-IP" or
"static IP".
1 or more PCs and 1 or more R&S TSME6 devices per LAN interface, either
connected directly or via a L2 switch
Each of the PC’s LAN interface physically connected to the subnetwork must
not receive an IP from a DHCP server. (The IP address generated for PC must
match the following pattern: 169.254.X.Y.)
Configure all R&S TSME6 devices on the same LAN interface with stored IP
addresses in the ranges 169.254.0.1 – 169.254.0.255 (inclusive) or
169.254.255.0 – 169.254.255.254 (inclusive), and use unique IP addresses.
These ranges are important to prevent conflicts with IP addresses dynamically
generated for the PC LAN interfaces.
Note: If a R&S TSME6 is shared with 2 or more PCs, and its stored IP address
is not in the defined range above, it leads in rare cases to IP conflicts. It is
therefore recommended to respect this rule.
"Static IP" mode
1 or more PCs and 1 or more R&S TSME6(s), either connected directly or via a
L2 switch.
Other network devices are permitted, as long as all IP addresses used are
unique.
This section describes how to configure the LAN interface for a single R&S TSME6. It
includes the following topics:
Configuring the LAN interface on the host PC........................................................ 19
Firewall configuration.............................................................................................. 21
Connecting the R&S TSME6 to the host PC...........................................................21
Preparing for use

Table of Contents

Related product manuals