Starting the engine
7.3 Starting the engine
WARNING!
Potentially fatal injuries due to the engine taking in flammable gases!
Do not operate the engine in areas with a heavy concentration of
flammable vapors such as e. g. diesel, gas or propane.
When handling flammable liquids and gases, always shut off the
engine immediately.
WARNING!
Shear hazard in the area of the extinguishing device!
Body parts can be sheared off.
Do not remain in the danger area.
WARNING!
Serious injuries can arise through failure to use protective equipment.
Wear protective equipment.
DANGER!
Inhalation of toxic exhaust fumes can cause death or serious damage
to health!
During operation of internal combustion engines in confined spaces, toxic
gases build up. In order to properly discharge hot exhaust gases, use the
provided, standardised exhaust hose. If operation of internal combustion
engines in enclosed spaces is necessary, note the following:
Extract the exhaust gases by means of the exhaust gas hose.
Ensure there is adequate ventilation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosenbauer FOX and is the answer not in the manual?

Rosenbauer FOX Specifications

General IconGeneral
Pump TypeCentrifugal
Max Pressure10 bar
TypePortable Fire Pump
Priming SystemAutomatic
Engine Type4-stroke petrol engine