Technical description
39 / 97
Optional equipment
6.4 Optional equipment
Exhaust gas hose
DANGER!
Inhalation of toxic exhaust fumes can cause death or serious damage
to health!
During operation of internal combustion engines in confined spaces, toxic
gases build up. In order to properly discharge the hot exhaust gases, use
the provided, standardized exhaust gas hose. The hose outlet should not
be within the area of operation. An exhaust gas hose that is too short or too
long may cause the device to trap heat and thus endanger the machine and
subsequently also the operator. An exhaust gas hose compliant with DIN
14572, with a minimum diameter of 50 mm and a maximum length of 1.5
metres must be used. If no exhaust gas hose is used, then position the unit
so that the exhaust gases can be freely discharged from the device.
Operation in the immediate vicinity of flammable material and substances
is prohibited. The exhaust system becomes hot during operation. Allow the
exhaust gas hose to cool down after operation before it is removed. If
operation of internal combustion engines in enclosed spaces is necessary,
note the following:
Extract the exhaust gases by means of the exhaust gas hose.
Ensure there is adequate ventilation.
with 2 wooden handles, in accordance with DIN14572, W=50 mm, L=1500
mm
Exhaust gas hose DIN 14572

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosenbauer FOX and is the answer not in the manual?

Rosenbauer FOX Specifications

General IconGeneral
Pump TypeCentrifugal
Max Pressure10 bar
TypePortable Fire Pump
Priming SystemAutomatic
Engine Type4-stroke petrol engine