Technical data
93 / 97
Noise measurements
11.1 Noise measurements
PFPN 10 - 1000
PFPN 10 - 1500
15 bar / 1000 l/min
The values are in accordance with the noise measurement of EN 14466:
2008, Annex E, determined by applying the standards EN ISO 3744 and EN
ISO 11203
The sum of a measured noise value and its associated uncertainty factor
represent the upper limit of the range of values that could occur during mea-
surements.
Unit
Dry weight approx. 150 kg (without fluids)
Operating weight approx. 166 kg (full 20 l tank)
Dimensions (L x W x H) approx. 923 x 636 x 845
Volume approx. 0.498 m³
Operating range -15 °C to +35 °C ambient tempera-
ture (EN14466)
Sound pressure level, L
p(ST)
based on 20μPa, at the
operating position
94.9 (dB)
Uncertainty factor, K
p(ST)
2 (dB)
Acoustic power emissions, L
WA
based on 1µW 109.4 (dB)
Uncertainty factor, K
WA
2 (dB)
Sound pressure level, L
p(ST)
based on 20μPa, at the
operating position
95.8 (dB)
Uncertainty factor, K
p(ST)
2 (dB)
Acoustic power emissions, L
WA
based on 1µW 110.3 (dB)
Uncertainty factor, K
WA
2 (dB)
Sound pressure level, L
p(ST)
based on 20μPa, at the
operating position
100 (dB)
Uncertainty factor, K
p(ST)
2 (dB)
Acoustic power emissions, L
WA
based on 1µW 114.5 (dB)
Uncertainty factor, K
WA
2 (dB)