Technical description
35 / 89
LCS operation panel
Pilot lamps
Symbol Name Functional description
ECO mode
(optional)
The control shows the condition of the
speed reduction.
The pilot lamp has three switching condi-
tions:
Grey: preselected
Green: active, speed lowered
Black: deactivated
Active output con-
trol - APC
The control indicates a possible over-
heating of the power generator.
The output power is automatically re-
duced to prevent overheating.
The pilot lamp has two switching posi-
tions:
Green: APC active, output power re-
duced
Grey: APC deactivated, normal op-
eration
External refuelling
The control shows the condition of the ex-
ternal refuelling.
The pilot lamp has three switching condi-
tions:
Green: active, fuel tank is being filled
Grey: preselected, level in fuel tank
above the switch-on threshold
Black: deactivated
Red: error
Voltage monitoring
of the phases
The control shows the state of the voltage
at the corresponding phase.
The pilot lamp has three switching condi-
tions:
Green: normal operation
Black: phase deactivated / generator
off
Red: voltage too high/too low
ECO
APC
Ux