Service and cleaning
72 / 89
Service work
• K228 External refuelling (fill level sensor)
Diode:
• Freewheeling diode starter relay
8.5.5 Fuse strip
The fuse strip is located below the battery compartment cover. If an over-
load occurs due to a consumer, the circuit breaker is activated. An addition-
al message is output on the control unit.
The circuit breakers may only be replaced by trained specialist personnel.
After replacement, a new sealing tape must be fitted between the GFRP
parts to prevent moisture from penetrating. After the replacement of a circuit
breaker, the power generator shall be subjected to a periodic test. Take
note of general dangers that could occur during assembly.
8.5.6 Main breaker
The following circuit breakers are used:
Main breaker
Tripping current in [A]
thermal magnetic
ABL B16 with special characteristic
3L+N
16 80 - 100
ABL B16 with special characteristic L+N 16 80 - 100
ABL B16 L+N 16 48 - 80
ABL B20 2L 20 60 - 100
ABL B20 3L+N 20 60 - 100
ABL B13 L+N 13 39 - 65
ABL C10 3L+N 10 50 - 100
ABL auxiliary contact (for monitoring) - -