Operation
55 / 89
Operation
The voltage is regulated by an integrated voltage regulator.
The power generator may have different sockets, voltages and fre-
quencies for special devices.
Connect consumer
When using loads equipped with intelligent voltage monitoring devices (e.g.
undervoltage detection, direction of rotation detection, frequency monitor-
ing, etc.), it must be ensured by the user before start-up that these voltage
monitoring devices also comply with the characteristics of a portable power
generator (especially with regard to the start-up situation).
Start the power generator in normal operation.
See chapter "Start power generator".
Operate the power generator for approx. 2 mins without load.
Activate Circuit breakers and Polarity reversing switch.
Open the socket covers and plug in the consumer(s).
Switch on consumer.
The total power consumed must not exceed the maximum rated power of
the power generator.
7.6.4 Shut down power generator
Disconnect consumer
Switch off consumer and pull the plug out of the socket.
Close the socket covers.
Operate the power generator for approx. 2 mins without load.
Shut down power generator
CAUTION!
Danger of burns due to touching the hot engine and engine
components!
Do not linger in the danger zone.
Do not touch hot parts of the engine.
Do not touch any parts of the exhaust system.
Wait until all parts have cooled down.
After shutting down the power generator, misfiring may occur.
Do not remain in the danger area.
Do not shut down the power generator with consumers connected.