move it towards the cam (3) at a
distance of 1 to 3 mm;
tighten the nuts properly
7.11.7 AUXILIARY LIFT MAX HEIGHT LIMIT SWITCH ADJUSTMENT (rif. Figure 29)
With the lift-table operating, press Up button (7) and check the lift stops at 450 mm height.
Fig.33
If this does not happen ad just the limit switch as
follow (installed on platform P2) :
With the lift-table operating, press Up
button (7) and raise it at a height of 450
mm from lift platform; if the limit switch
operates before such height, press the UP
button (7) and the exclusion button (15)
simultaneously.;
loosen dowels which fix the cam to the
arm and turn it until the limit switch
detects it presence;
tighten the dowels properly
if the limit switch does not detect the cam, ad
just it as follow:
loosen nuts (2) of sensor (1), installed
on external arm of auxiliary lift P2, and
move it towards the cam (3) at a
distance of 1 to 3 mm;
tighten the nuts properly
7.11.8 WORKING POSITION LIMIT SWITCH ADJUSTMENT
Le posizioni di lavoro vengono regolate dalla casa costruttrice ma possono essere cambiate a
seconda delle necessità dell’utilizzatore nel campo tra l’altezza minima e massima
Fig.34
When working position buttons (13) and (14) are
pressed, the platform reach max height without
stopping at any intermediate height, the limit
switches must be adjusted as follow:
raise the lift to 1
st
working position by
pressing correspondent button.;
loosen dowels (4) which fix the cam (3) to
the arms of the platform P1 and turn cam
(3) until the sensor detects it, and
correspondent led on display switches on ;
tighten dowels properly
if the limit switch does not detect the cam, ad just
it as follow:
loosen nuts (1) of sensor (2), and move it
towards the cam (3) at a distance of 1 to 3
mm;
tighten the nuts properly
Repeat the same operation to set 2
nd
working position limit switch