9 CHAPTER 9 - MAINTENANCE
ONLY TRAINED PERSONNEL WHO KNOWS HOW THE LIFT WORKS, MUST BE ALLOWED TO
SERVICE THE LIFT .
To service the lift, the properly following has to be carried out:
use only genuine spare parts as well as equipment suitable for the work required
follow the scheduled maintenance and check periods shown in the manual
discover the reason for possible failures such as too much noise, overheating, oil blow-by,
etc.
Refer to documents supplied by the dealer to carry out maintenance:
Refer to functional drawing of the electric and hydraulic equipment
Refer to exploded views with all data necessary for spare parts ordering
Refer to list of possible faults and relevant solutions..
Before carrying out any maintenance or repair on the lift, disconnect the power
supply, padlock the general power supply switch and keep the key in a safe place
to prevent unauthorized persons from switching on or operating the lift
9.1 ORDINARY MAINTENANCE
The lift has to be properly cleaned at least once a month. Use a self-cleaning cloth.
THE USE OF WATER OR FLAMMABLE LIQUID IS STRICTLY
FORBIDDEN
Be sure the rod of the hydraulic cylinders is always clean and not damaged since this may result in
leakage from seals and, as a consequence, possible malfunctions.
9.2 PERIODIC MAINTENANCE
Every 3 months
Hydraulic circuit
check oil tank level; refill with oil, if needed;
check the circuit for oil leakage.
Check seals for proper conditions and replace
them, if necessary;
Foundation bolts
check bolts for proper tightening
Hydraulic pump
verify that no noise changes take place in the pump
of the control desk when running and check fixing
bolts for proper tightening
Safety system
check safety devices for proper operation
Every 6 months
Oil
Check oil for contamination or ageing.
Contaminated oil is the main reason for failure of
valves and shorter life of gears and pump
Ogni 12 mesi
Controllo generale
verify that all components and mechanisms are not
damaged
Impianto elettrico
a check of the electrical system to verify that
control desk motor, limit switches and control
panel operate properly must be carried out by a
skilled electrician