- Apply the weight and position it perfectly to the "12
o'clock".
- Press the button and close the guard to per-
form the 2nd spin of the wheel (100 g weight placed
on the outside of the wheel).
- At the end the following screen will appear on the
monitor, suggesting to remove the weight of 100 g
previously applied on the outer side and apply it on
the inside of the rim.
- Turn manually the wheel until you have the weight of
100 g on the outer side at "12 o'clock".
- Press the brake pedal and hold it down during the
whole the following operation to avoid unexpected
rotation of the spindle.
- Remove the weight from 100 g from the outside of the
wheel and apply it on the inner side at "12 o'clock".
- Close the guard to perform the 3rd spin of the wheel
(100 g weight placed on the inside wheel).
At the end of the rotation, the video screen below will
be displayed to indicate that the operation is finished.
WHEN THE OPERATION IS CON-
CLUDED, REMOVE THE WHEEL
FROM THE MANDREL AND PER-
FORM A COMPLETE CALIBRA-
TION PROCEDURE “0” (ZERO)
MANDREL AS DESCRIBED IN PAR.
14.2.1.
14.2.3 Gauge calibration
Press the button (Fig. 45 ref. 3) to display the
following screen page on the monitor:
1 2
KEY
1 – Distance-diameter caliper calibration
2 Calibration of external data gauge/automatic
external data gauge
Fig. 46
Distance-diameter caliper calibration
Press the button
(Fig. 46 ref. 1) to display the
following screen page on the monitor:
1297-M008-8