2.2) Operating media-Coolant
General note
Conventional
coolant
Conventional coolant mixed with water has the advantage of a
higher specific thermal capacity than water-less coolant.
Application When correctly applied, there is sufficient protection against vapor
bubble formation, freezing or thickening of the coolant within the
operating limits.
Use the coolant specified in the manufacturers documentation.
Mixture
WARNUNG
NOTICE
Obey the latest edition of Service Instruction
SI-912 i-001 for the selection of the correct
coolant.
WARNUNG
NOTICE
Obey the coolant manufacturers instructions
about the coolant mixture.
mixture ratio %
designation concentrate water
Conventional e.g. BASF Glysantine Pro-
tect Plus G48 anticorrosion
50 50

Table of Contents

Other manuals for Rotax 912 i series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 i series and is the answer not in the manual?

Rotax 912 i series Specifications

General IconGeneral
Number of Cylinders4
Max Power100 hp (73.5 kW)
Max Power Output RPM5800 rpm
Ignition SystemDual electronic ignition
Oil SystemDry sump, forced lubrication with separate oil tank
Reduction Gear Ratio2.43:1
TBO2000 hours
Engine Type4-stroke, horizontally opposed
Displacement1352 cm³
Bore x Stroke84 mm x 61 mm
Max Torque128 Nm
Fuel TypeAvgas 100LL or unleaded automotive gasoline
Fuel SystemElectronic fuel injection
Cooling SystemLiquid/air-cooled