Effectivity: 912 i Series BRP-Powertrain page 4-6
OM Edition 1/Rev. 0 January 01/2012
d05873.fm
4.14) Maximum permissible exhaust temperature exceeded
Exceeded ex-
haust temperature
- Check the exhaust temperature.
- Oil and coolant limits must not be exceeded.
- A maintenance inspection should be carried out.
4.15) EMS voltage supply below the minimum required level
Voltage supply be-
low level
- Limited flight operation is possible if the voltage (alternator A
or B) is OK here.
- Proceed according to section: „Failure of the EMS power sup-
ply“ if this shows no effect.
- A maintenance inspection should be carried out.
4.16) The sprag clutch decouples not from the starter
Spag clutch is per-
manently in en-
gagement position
- Move the throttle lever to the idle position.
-Set the EMS main switches to “OFF“.
- Switch both LANE select switches to “OFF“.
- A maintenance inspection should be carried out.
Reduce engine power setting to the minimum
necessary and carry out precautionary land-
ing.
Reduce engine power setting to the minimum
necessary and carry out precautionary land-
ing.
Switch the engine “OFF“. Risk of fire and dan-
ger of the electric starter overheating.