1.3) Coolant types
General note In principle, 2 different types of coolant are permitted:
Conventional
coolant
Conventional coolant is recommended as it commonly available and has a
greater thermal heat transfer capability. Its limitation is its lower boiling
point.
Waterless cool-
ant
Waterless coolant is recommended if the design of the aircraft can not
maintain the coolant temperature limit.
Mixing ratio
Boiling point Conventional coolant:
Conventional coolant with a rate of 50 % water cannot boil at a tempera-
ture below 120 °C (248 °F) at a pressure of 1.2 bar (18 psi). The max.
coolant temperature limit is therefore 120°C (248 °F).
Permanent monitoring of coolant temperature and cylinder head tempera-
ture is necesssary.
Description
1 Conventional coolant based on ethylene glycol
2 Waterless coolant based on propylene glycol
WARNUNG
NOTICE
When selecting a suitable coolant, the information in
Service Instruction SI-912-016, latest issue, must be
observed.
WARNUNG
NOTICE
The manufacturers instructions regarding the coolant
must be observed.
Mixing ratio
Description Concentrate Water
Conventional coolant 50 % 50 %
Some conventional coolant is available pre-mixed by the manufacturer. In this case do
not mix with water, instead follow the manufacturers instructions..
Waterless coolant 100 % 0

Table of Contents

Other manuals for Rotax OM-912

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax OM-912 and is the answer not in the manual?

Rotax OM-912 Specifications

General IconGeneral
BrandRotax
ModelOM-912
CategoryEngine
LanguageEnglish

Related product manuals