2.2) Rectifier regulator
Type Electronic full-wave rectifier regulator.
Output voltage 14.2 V± 0.3 (from 1000 ± 250 rpm).
Current limit Current limit:
Max. 22 A.
Component tem-
perature
Max. permissible component temperature:
+80 °C (176 °F) (measured in area (1)).
NOTE: The performance specifications are given for optimal
cooled components. If necessary, use a separate heat sink
for the rectifier regulator.
Weight See chap. 72-00-00 section: weight.
Graphic Connection
Fig. 2 08631
Part Function
1 Area component temperature
2 Description of connections:
G = yellow - from generator
R = red - to battery, positive terminal
B = battery positive terminal
L = warning lamp circuit
C = control or field circuit
G
G
R
L
C
B
62 (2.44 in.)