Communicator | 3.05 18
5.1.2.1 Configuring the Telephone Modem
Select SYSTEM > Advanced Setup > Line Modem.
This screen defines the line modem specifications.
AUTO ANSWER: Number of rings before the Communicator automatically answers a
dialed-in call. For example: if set to 4 the Communicator answers a call after four rings.
LINE TEST: Monitors the phone line and activates an alarm in case of disconnection.
Default: YES.
INPUT GAIN: For factory use only. If your Communicator is unable to connect your voice dial
in phone line, consult your local dealer regarding this feature.
VOICE DIAL-IN: This option enables the user to call in at any time and receive information
from the communicator regarding alarms. To receive the information in voice mode only:
1. Call the controller, wait for one ring less than the AUTO ANSWER set parameter number
and hang up.
2. Wait at least five seconds (but no longer than 60 seconds) and then call again. Follow
the instructions given by the controller.
If the AUTO ANSWER parameter is set to zero (0), then the Communicator answers in voice
mode.
If the AUTO ANSWER parameter is set to zero and the VOICE DIAL IN parameter is set to
YES, the controller answers in voice mode every time.
5.1.2.2 Defining when Communicator Answers Incoming Calls
1. Select SYSTEM > Advanced Setup > GSM.
2. In Auto Answer, define the number of rings until the Communicator answers through the
cellular modem.
CELLULAR MODEM
TEXT FROM Addr. Book
Auto Answer 2
Operator STD
LINE MODEM
AUTO ANSWER 4
LINE TEST YES
DIAL DELAY ( , ) 2
INPUT GAIN 70
VOICE DIAL-IN YES