Communicator | 3.05 22
5.3.1.3 Status Report
Upon a user request, Communicator sends a status report on basic house functions and animal
statistics. The report includes the following specifications:
Target Temp
Average Temp
Vent Level
Vent Mode (minimum ventilation, natural, tunnel)
Humidity
Weight (current average animal weight)
Pressure (static pressure)
Water Control (daily water consumption)
Feed Count (daily feed consumption)
Mortality
By default, the report only includes Target Temp, Average Temp, Vent Level and Humidity.
NOTE: Platinum Controllers, Version 3.0 and higher, support this function.
To select the parameters:
1. Go to SYSTEM > Advanced Setup > GSM.
2. Use the +/- key to select the required parameter.
3. Press Enter to select/deselect the parameter.
4. Press Save.
The parameters are configured.
To receive a status report:
Receiving the Report for One House
?SX > 'Send SMS' to the Communicator cell phone number.
? = Start of message
S = Status report
X = Represents house number (can be any positive number from 1 - 64)
Receiving the Report for Several Houses
?SX#X#X > 'Send SMS' to the Communicator cell phone number
? = Start of message
S = Status report
X = Represents house number (can be any positive number from 1-64)
# = Sign separates between every house number