Communicator | 3.05 40
10.2 Event Codes
Table 1 lists the event codes sent in text messages.
Table 3: Event Codes
Event Code LCD Message
1 "power off "
2 "power on"
3 "cold start"
4 "error-01"
5 "test running"
6, 7 , 9, 10, 11, 12, 16, 17 "fail"
8, 13 "no answer "
14 "page sent "
18 "text sent "
19, 20 "ack alarm "
21 "disable alarm "
22, 23, 24 "low signal"
10.3 Advanced Alarm Settings
The following sections detail the advanced alarm functions. Basic alarms are set up in the Initial
Configuration.
• Resetting the Alarms, page 40
• Disabling Alarms, page 41
• Defining the Message Delay, page 41
• Defining the Message Repeat Parameter, page 41
• Defining the Internal Alarms, page 42
• Defining the Internal Alarms, page 42
• Defining the Battery Alarm, page 42
10.3.1 Resetting the Alarms
• Go to ALARM > Reset.
This menu resets the alarms of any controller that exists within the network. The Communicator’s unit
number is 0.
Use the +/- key to navigate to the required unit number.
TO RESET PRESS ENTER
UNIT =