EasyManuals Logo

rotork gp series User Manual

rotork gp series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
Keeping the World Flowing
79
18.0 Grease & Hydraulic Oil Specification
This is the standard oil specification for Rotork Fluid Systems hydraulic
manual override and hydraulic cylinders working at temperature
between -40 °C and +100 °C for ATEX and non-ATEX application.
Manufacturer: MOBIL
Trade Name: DTE 10 EXCEL 15
ISO Viscosity Grade: 15
Viscosity, ASTM D 445
cSt @ 40 °C
cSt @ 100 °C
15.8
4.07
Viscosity Index, ASTM D 2270 158
Brookfield Viscosity ASTM D 2983 cP @ -40 °C 2620
Tapered Roller Bearing (CEC L-45-A-99), %Viscosity Loss 5
Density 15 °C, ASTM D 4052, kg/L 0.8375
Copper Strip Corrosion, ASTM D 130, 3 hrs @ 100 ºC 1B
Pour Point, °C, ASTM D 97 -54
Flash Point, °C, ASTM D 92 182
Foam Sequence I, II, III, ASTM D 892, ml 20/0
Dielectric Strength, ASTM D877, kV 45
Acute Aquatic Toxicity (LC-50, OECD 203) Pass
This is the standard oil specification for Rotork Fluid Systems hydraulic
manual override and hydraulic cylinders working at temperature
down to -60 °C for non-ATEX applications.
Manufacturer: MOBIL
Trade Name: UNIVIS HVI
ISO Viscosity Grade: 32
Viscosity, ASTM D 445
cSt @ 40 °C
cSt @ 100 °C
13.5
5.3
Viscosity Index, ASTM D 2270 404
Kinematic Viscosity @ -40 ºC, ASTM D 445 371 cST
Copper Strip Corrosion, ASTM D 130 1A
Pour Point, °C, ASTM D 97 -60 °C
Flash Point, °C, ASTM D 92 101 °C
This is the standard oil specification for Rotork Fluid Systems hydraulic
manual override and hydraulic cylinders working at temperature
between -60 °C and +90° C for ATEX application.
Manufacturer: TECCEM
Trade Name: SynTop 1003 FG
ISO Viscosity Grade: 3
Viscosity, ASTM D 445
cSt @ -40 °C
cSt @ -55 °C
cSt @ 40 °C
73
2.6
3.2
Pour Point, °C, ASTM D 97 -88 °C
Flash Point, °C, ASTM D 92 140 °C
Density 20° C, kg/L 0.86
An alternative oil may have been specified for your application. Please refer to the job specific documentation.
A4 US
US
A4
US
A4
A4 US

Other manuals for rotork gp series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the rotork gp series and is the answer not in the manual?

rotork gp series Specifications

General IconGeneral
EnclosureIP66
Communication ProtocolsFoundation Fieldbus
InputsDigital
OutputsDigital, Relay
DisplayLCD
Protection RatingIP66
Hazardous Area CertificationATEX, IECEx
Power Supply24 VDC, 115 VAC, 230 VAC

Related product manuals