EasyManuals Logo

rotork gp series User Manual

rotork gp series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Installation, Commissioning and Maintenance Manual
78
18.0 Grease & Hydraulic Oil Specification
QUANTITY OF GREASE IN HOUSING
Center body size Qty (kg)
065 0,3
085 0,3
100 0,3
130 0,4
161 0,5
200/201 0,5
270/271 0,8
350 1,2
Use following grease or equivalent to lubricate the manual
override jackscrew and seals of pneumatic cylinders.
Manufacturer: SHELL
Trade name: GADUS S5 V25Q
NLGI grade: 2.5
Colour: Clear Brown
Penetration, density, viscosity
Viscosity of oil at 40 °C (ASTM D445):
Viscosity of oil at 100 °C (ASTM D445):
25 cST
4.8 cST
Temperature
Drop point (IP396):
180 °C
18.2 Hydraulic Oil
This is the standard oil specification for Rotork Fluid Systems
hydraulic manual override and hydraulic cylinders working at
temperature between -20 °C and +100 °C for ATEX and non-
ATEX application.
Manufacturer: MOBIL
Trade Name: DTE 10 EXCEL 32
ISO Viscosity Grade: 32
Viscosity, ASTM D 445
cSt @ 40 °C
cSt @ 100 °C
32.7
6.63
Viscosity Index, ASTM D 2270 164
Brookfield Viscosity ASTM D 2983, cP @ -20°C 1090
Brookfield Viscosity ASTM D 2983 cP @ -30°C 3360
Brookfield Viscosity ASTM D 2983 cP @ -40°C 14240
Tapered Roller Bearing (CEC L-45-A-99), %Viscosity Loss 5
Density 15° C, ASTM D 4052, kg/L 0.8468
Copper Strip Corrosion, ASTM D 130, 3 hrs @ 100 ºC 1B
Rust Characteristics, ASTM D 665B Pass
FZG Gear Test, DIN 51534, Fail Stage 12
Pour Point, °C, ASTM D 97 -54
Flash Point, °C, ASTM D 92 250
Foam Sequence I, II, III, ASTM D 892, ml 20/0
Dielectric Strength, ASTM D877, kV 49
Acute Aquatic Toxicity (LC-50, OECD 203) Pass
A4US
US
A4
US A4
US
A4

Other manuals for rotork gp series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the rotork gp series and is the answer not in the manual?

rotork gp series Specifications

General IconGeneral
EnclosureIP66
Communication ProtocolsFoundation Fieldbus
InputsDigital
OutputsDigital, Relay
DisplayLCD
Protection RatingIP66
Hazardous Area CertificationATEX, IECEx
Power Supply24 VDC, 115 VAC, 230 VAC