IQ and IQT full configuration,
status and monitoring user manual
IQ Multi-Turn and IQT Part-Turn
Electric Valve Actuators
IQ Range
Question and Answer IconNeed help?

Do you have a question about the rotork IQ Range and is the answer not in the manual?

Summary

Introduction to Rotork IQ Actuator Manual

Using the Rotork Setting Tool

Guide to using the Rotork Setting Tool for actuator navigation and settings adjustment.

Connecting to the Actuator

Instructions for establishing communication with the actuator via Bluetooth or Infrared.

Password Security Management

Procedures for setting, changing, and managing actuator access passwords.

Actuator Settings Configuration

Configuring Actuator Limits

Setting operational limits (open, close, torque, speed) for actuator control.

Control Mode Configuration

Setting local and remote control modes, interlocks, and communication protocols.

Emergency Shut Down (ESD) Configuration

Configuring ESD actions, overrides, and network disable for safety.

Actuator Status Monitoring

Alarm Status and Interpretation

Displaying current actuator alarms and their meanings for troubleshooting.

Actuator Data Logging and Analysis

Summary

Introduction to Rotork IQ Actuator Manual

Using the Rotork Setting Tool

Guide to using the Rotork Setting Tool for actuator navigation and settings adjustment.

Connecting to the Actuator

Instructions for establishing communication with the actuator via Bluetooth or Infrared.

Password Security Management

Procedures for setting, changing, and managing actuator access passwords.

Actuator Settings Configuration

Configuring Actuator Limits

Setting operational limits (open, close, torque, speed) for actuator control.

Control Mode Configuration

Setting local and remote control modes, interlocks, and communication protocols.

Emergency Shut Down (ESD) Configuration

Configuring ESD actions, overrides, and network disable for safety.

Actuator Status Monitoring

Alarm Status and Interpretation

Displaying current actuator alarms and their meanings for troubleshooting.

Actuator Data Logging and Analysis

rotork IQ Range Specifications

General IconGeneral
Position SensingAbsolute encoder
Torque RangeUp to 3000 Nm
Communication ProtocolsModbus, Foundation Fieldbus, Profibus
Ingress ProtectionIP68
Data LoggingYes, data logging
Diagnostic CapabilitiesComprehensive diagnostics
DisplayLCD