Ruby Tech GS-2224L - 3-6-4.Storm Control

Default Icon
301 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
7
3-6-4.Storm Control
Function name:
Storm Control Configuration
Function description:
The switch support storm ingress policer control function to limit the Flooded,
Multicast and Broadcast to prevent storm event happen.
Parameter description:
Frame Type:
There three frame types of storm can be controlled: Flooded unicast /
Multicast / Broadcast
Status:
Enable/Disable Selection: means enabled, means disabled
Rate(pps):
Refer to the following rate configurable value list, the unit is Packet Per
Second (pps).
1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1K / 2K / 4K / 8K / 16K / 32K /
64K / 128K / 256K / 512K / 1024K