KT332N Cutting &engraving control system user manual V1.1
13
protection 1.
Water protection input must use 24V voltage input
5
L-AN
Laser power analog signal output. For glass tube laser power
supply, it is recommended to use this pin for power signal.
Prompt
Please select the correct laser type in the factory parameter settings.
When a glass laser tube is used, and the control signal cable is very long
from the controller to the laser power, if L-AN is for the power control, the
long cable will cause interference and make the laser power unstable. So
for this situation, PWM signal can replace the L-AN to control the glass
tube’s power. And decrease the interference.

Related product manuals