2 Periodic Inspection
d. The pressure between the metering roller
and
water oscillating roller (C)
Checking procedures
----------------------------,
Shift the metering roller release lever
in
the direction
of
the arrow
(
~
position) to contact the metering roller with the water fountain
roller.
At this time, set the water volume control dial to "0".
Run the press.
Shift the water roller cleaning lever
in
the direction
of
the arrow
(
~
position) and contact the bridge roller with the water oscillating
roller, to apply ink on the water oscillating roller.
After
that, shift the
water
roller cleaning
lever
back
to the
~
position.
Stop the press.
Push the water form roller
ON
button to contact the metering roller
with the water oscillating roller.
After a few seconds, push the water and ink form roller
OFF
button
to release the metering roller from the water oscillating roller.
«NOTICE»
Be sure to push the water
and
ink
form roller
OFF
button to
release the metering roller from the water oscillating roller.
If
rotating the rollers with the metering roller contacting the
water oscillating roller, the metering roller surface
and
water
fountain roller motor will
be
damaged.
Maintenance Edition - 19