Error
message
Cause
Countermeasure
E-*1
The
air cylinder for the leading edge clamp
Please contact your service technician.
closing does not return.
The plate load air cylinder does not return.
Remove the plate manually.
( • Operation Edition- 74)
E-*2
(When stopping the plate mounting or removing,
(Note)
1.
Crawl
the
press
in
the
forward
this may be indicated.)
direction and set the hexagon head
bolt in the center
of
the hole on the
The plate remove air cylinder does not return.
left side
of
the plate cylinder.
If
the
E-*3
(When stopping the plate mounting or removing,
press
cannot
be
crawled
in
the
this may be indicated.)
forward direction, crawl the press in
the reverse direction a little first and
~
then crawl in the forward direction.
2.
When the plate mounted indication
E-*5
lamp lights, do the removing process
without a plate.
( • Operation Edition - 22)
The tail edge insertion device does not move
The tail edge insertion device may not be able
E-*4
forward up to the setting position,
or
does not
to move
if
the gum solution, ink, and so on are
return correctly to the standard position.
stuck on it. Please clean the tail edge insertion
device. ( • Maintenance Edition - 9)
Please
wipe
off
the plate
cylinder
0
point
detector sensor (1) with a dry soft rag.
J
E-*6
The plate cylinder 0 point detector sensor does
~~~
not detect the standard position.
~@
'@
'ULJUU#
E-*7
The plate cylinder does not stop at the predeter-
Please contact your service technician.