26
• LIKELY CAUSES: 80v Batteries; TIC
• Testing Steps: (check function after each step)
1. Turn mower off
2. Unplug all 80v Batteries
3. Insert (1) battery and attempt to turn mower on
4. Repeat step 3. with each battery to test each battery
a. Replace any batteries found non-functional
5. Replace the TIC
6. Replace DC-DC Convertor
7. Visually inspect wiring for any obvious loose connections
8. Check fuses for continuity
a. 100A fuse is located in Junction Box
b. 4A fuse is located next to DC-DC Convertor
< Return to Table of Contents
No Power to Mower
Confidential and Proprietary - Property of Techtronic Power Equipment - DO NOT COPY or DISCLOSE
(Main Relay doesn’t click)