28
LIKELY CAUSES: Drive Motor Controller
Testing Steps: (check function after each step)
1. Ensure connections and wiring are secure
a. Check Brake Switch connection
b. Check Neutral Switch connection
c. Check LCD Panel connection
2. Replace Primary Drive Controller
3. Replace Secondary Drive Controller
< Return to Table of Contents
Park / Neutral Light Malfunction
Confidential and Proprietary - Property of Techtronic Power Equipment - DO NOT COPY or DISCLOSE
Neutral Indicator
(Joystick locked)
Parking Brake
Indicator
Primary Deck Motor
Controller has the large
square connector.
Brake Switch