54
< Return to Table of Contents
Error Codes (continued)
Confidential and Proprietary - Property of Techtronic Power Equipment - DO NOT COPY or DISCLOSE
INDICATOR CODE MEANING BIT MEANING
B2 Deck Controller data2
7 Seat Switch is not closed
6 PTO switch is not closed
5 Error with the seat and PTO logic
4 F gear
3 R gear
2 RMO enable flag
1 NOT USED
0 NOT USED
B3 Deck Controller data3
7 Undervoltage protection (secondary control 1)
6 Overvoltage protection (secondary control 1)
5 Temperature protection (secondary control 1)
4 Stall protection (secondary control 1)
3 Motor out of step (secondary control 1)
2 Low speed protection (secondary control 1)
1 MCU self-test fault (secondary control 1)
0 NOT USED
B4 Deck Controller data4
7 Current sense circuit fault (secondary control 1)
6 High bridge MOSFET fault (secondary control 1)
5 Low bridge MOSFET fault (secondary control 1)
4 High and low bridge MOSFET short circuit fault (secondary control 1)
3 Communication failure 1
2 Communication failure 2
1 Communication failure 3
0 Communication failure 4