C. Constraints
1. IR KEY is not processed except for remote control return key while dehumidification mode is in progress
2. During dehumidification mode, AC OFF/ON of the right SYSTEM driver operates according to the "Auto-on" setting value.
3. If the AC of the left SCREEN driver is turned off/on while dehumidification mode is in progress, the dehumidification mode
is re-executed from the beginning only for the left SCREEN.
4. During dehumidification mode, WAKEUP signals transmitted to MDC (RS2323 terminal) and WOL (LAN terminal) other
than IR KEY are not exempted, so WAKEUP is performed in normal mode. Therefore, the WAKEUP signal should not be
transmitted to the MDC or WOL during dehumidification mode.
5. During the dehumidification mode, the purpose is to dehumidify the LED device, so a progress rate cannot be indicated.
6. If the remote control return key is terminated during dehumidification mode and the dehumidification mode is executed
again, the dehumidification mode proceeds again from the beginning.
7. During dehumidification mode, the contents set to OnTimer in the menu do not work.
8. Semi Auto Dehumidification mode does not work when Remote Configuration "ON" status or DPMS status.
Dehumidification guide Semi Auto
D. Environmental Information Confirmation Specifications
1. Factory Control The Wall Option Sensor option Dehumid option
Humidity Count XXX
Dehumid CNT XXX
Dehumid OFF Count XXX
Unused Time Count XXX
- When humidity is 80% or higher, Count (+1)
- When screen off status is 10 days or more in a row, Count (+1)
- When dehumidification mode is executed, Count (+1)
- When dehumidification mode is forcibly terminated, Count (+1)