SAMWONTECH
4th Edition of TEMI880 IM : Jan. 29. 2007 Page 44 / 119
Set value of the program pattern Set value of the time signal
Time signal operation within segment
Setting Time signal operation
1. ON TIME = 00.00
(Time Signal
NO : 04)
N SEG TIME
>= ON TIME
+ OFF TIME
It has not
influence on
next segment.
2. ON TIME 00.00
(Time Signal
NO : 05)
3. ON TIME = 00.00
(Time Signal
NO : 06)
N SEG TIME
< ON TIME
+ OFF TIME
4. ON TIME 00.00
(Time Signal
NO : 07)
Time Signal Operation
(N-1) SEG TIME
N SEG TIME
(N+1) SEG TIME
SEGMENT
OFF TIME
ON
OFF
TIME
SIGNAL3
(N-1) SEG TIME N SEG TIME
(N+1) SEG TIME
SEGMENT
OFF TIME
ON
OFF
TIME
SIGNAL4
OFF TIME
ON
OFF
(N-1) SEG TIME N SEG TIME (N+1) SEG TIME
TIME
SIGNAL1
SEGMENT
(N-1) SEG TIME
N SEG TIME
(N+1) SEG TIME
SEGMENT
OFF TIME
ON
OFF
TIME
SIGNAL2
ON TIME
ON TIME