82002-10
J
AIRDATA ANALOG
SANDEL
Vista, Ca.
B
16
ST3400 INSTALLATION DRAWING
Thursday, July 28, 2016
Title
Size Document Number Rev
Create: Sheet of
Category
Mod:Monday, July 02, 2001
82002-10
J
AIRDATA ANALOG
SANDEL
Vista, Ca.
B
16
ST3400 INSTALLATION DRAWING
Thursday, July 28, 2016
Title
Size Document Number Rev
Create: Sheet of
Category
Mod:Monday, July 02, 2001
82002-10
J
AIRDATA ANALOG
SANDEL
Vista, Ca.
B
16
ST3400 INSTALLATION DRAWING
Thursday, July 28, 2016
COMMENTS
A
REV
04/11/02
DATE
A/R 484 INITIAL RELEASE
B06/21/02 A/R 547 ADDED OAT
NOTES:
1.
02/21/03 C A/R 610 Depict J1 & J2 Seperately
F04/14/03 A/R 626 Moved OAT to Page 18
H02/18/04
A/R 675 Corrected pinout callouts on AZ-241.
Removed #2 Analog Airdata & added Penny &
Giles D60286
2.
See Manufacturer's Manual for Complete Interconnect
See Section 3, Interface Functions for OAT
Probe Requirements
Airdata Analog For GPWS Only
(No Altitude)
3.
Pressure Altitude Tolerance: Altitude +/- 500'; for
1000' change in altitude tolerance +/-100'
H103/17/04
A/R 690 Added note on Pressure Altitude and interface for the AZ-600.
SIGNAL COMMON
ALTITUDE RATE OUT
1
C
F
TA1 "TYPE 3"
1
TA1 "TYPE 3"
VS SIG IN
10
5
ST3400
INDICATED AIRSPEED
H
25
PENNY & GILES
D60286
PRESSURE ALTITUDE
ANALOG (Note 3)
40
SHIELD GROUND
BAROMETRIC ALTITUDE
VALID "HIGH"
J1
AIRDATA VALID IN
J1
SOFTWARE
SELECT
6
39
AIRDATA VALID IN
SHIELD GROUND
E
1
CIC
AIRDATA VALID OUT
TAS SIG IN
CBA "CIC 8800M"
7
CBA "P&G 20V PA"
39
BAROMETRIC ALTITUDE
J2
ST3400 (Mod A Only)
04077 MOD 3
ALTITUDE RATE
COMMON
25
38
SHIELD GROUND
CIC Airdata Analog For
GPWS Only (No Altitude)
G
BR1 "CIC BR+10V"
SOFTWARE
SELECT
VALID "HIGH"
BR1 "P&G ANALOG"
K
AIRDATA VALID OUT
VS SIG IN
J2
10
40
INDICATED AIRSPEED
SIGNAL COMMON
ALTITUDE PATE OUT
8
PRESSURE ALTITUDE
ANALOG (Note 3)
TAS SIG IN
12
66
31
Honeywell Analog
With Altitude
64
ALT 1 FINE Y
37ALT 1 FINE X
BR1 "ANALOG"
52
ALT 1 FINE SIN
26
AIRDATA VALID OUT
10
8
40
AIRDATA VALID IN
ALT DC COARSE IN
9
TA1 "TYPE 2"
TAS REF IN
ALT/VS1 GND SENSE
40
_
TAS REF OUT
VS REF- OUT
TA1 "TYPE 2"
29
TAS SIG OUT
VS REF+ IN
AZ-241
P1
39
24
ALT DC COARSE OUT
42
67
VS SIG IN
BR1 "ANALOG"
VS REF+ OUT
1
AZ-600
P1
ALT 1 FINE COS
VS REF- IN
23
VALID "HIGH"
CBA "S/C AC"CBA "S/C AC"
50
J1
34
VS SIG OUT
TAS SIG IN
54
ST3400
65
76
49
HONEYWELL
SOFTWARE
SELECT
VALID "HIGH"
SHIELD GROUND
25
ALT/VS1 GND SENSE
43
_
38
27
K
U
HONEYWELL
AZ-648
J
G
H
J07/01/04
A/R 717 Added interfaces for the
Honeywell AZ-648 & CIC 04077 Mod 3.
4.
Requires ST3400 Mod A
(See Note 4)
COMPUTER CONTROLLED DRAWING
DO NOT REVISE MANUALLY