*Note: C151b is inclusive of TSO C92 and the ST3400 may be used to
replace/upgrade C92 Ground Proximity Warning Systems
1.3.2 Physical Dimensions
The ST3400 is enclosed in an ARINC 408, 3ATI form factor enclosure and is
mounted to an instrument panel.
Form Factor:
3ATI (ARINC 408)
Width:
3.175 inches
Height:
3.175 inches
Length:
9.5 inches
Weight:
3.2 pounds with connectors and configuration module.
(Cable weight not included)
Mounting:
Clamp
Display:
1 mega-pixel, 256 color (144,000 color triad)
1.3.3 Operational Characteristics
Temperature/Altitude:
-20° C to +70° C / up to 55,000 F
Power Input: 28VDC nominal, 40 watt maximum. Operating range
22VDC 33VDC
Cooling Requirements: Internal fan. Requires ambient air at fan input along
the four corners of the 3ATI case.
82002-IM-L ST3400 INSTALLATION MANUAL
1-15

Table of Contents

Related product manuals