SINUS MINI High performance Vector Control Inverter User Manual
42
FD.19
reserved
+
FD.20
reserved
+
FE.00
Keyboard
frequency setting
lock function
0: Keyboard frequency settings are not locked, you
can change the frequency of the inverter settings
by keyboard keys
1: Keyboard frequency setting lock, can not change
the setting frequency of the inverter by keyboard
increase key and decrease keys, You can only
change the setting frequency of the inverter by
changing the F0.11
0
+
FE.01
Terminal start
delay
0.1-20.0s
0
FE.02
Terminal stop
delay
0.1-20.0s
0
FE.03
MODBUS respond
0The Modbus protocol responds to the write
command
1The Modbus protocol does not respond to write
commands
0
FE.04
Acceleration and
deceleration time
switching
frequency
When the frequency is not equal to 0, less than
FE.04, the Acc/Dec time is 1, otherwise the
Acc/Dec time is 2
0.00
+
FF.xx
Reserved
Reserved
Reserved
FH.00
Running display
parameters
selection
0: Frequency setting
1: Running frequency
2: Output current
3: Output voltage
4: Bus voltage
5: Overload rate
6: Preset line speed
7: Running line speed
1
#