【9】SPECIFICATIONS
9-1 General Specifications
AC Rectifier Form
:Half-wave rectifier form
Meter type :Internal magnet type, Taut band meter
Accuracy Assurance Temperature/Humidity Range
:21〜25 ℃ 75 %RH max. No condensation
Operating Temperature/Humidity Range
:3〜43 ℃ 80 %RH max. No condensation
Storage temperature/Humidity Range
:−10〜50 ℃ 70 %RH max. No condensation
Internal Battery :R6P (IEC) or UM-3 1.5 V×2
*Factory-preinstalled built-in battery
A battery for monitoring is preinstalled before shipping, therefore it may run down
sooner than the battery life specified in the instruction manual.
The ”battery for monitoring” is a battery to inspect the functions and specifications of
the product.
Internal fuse :φ5×20 mm F500 mAH/250 V
Fast fuse Blowout capacity 300 A
Dimension and Mass
:144(H )× 99(W )× 41(D )mm・approx.270g
Accessories :Instruction manual 1 Spare fuse 1
Test leads(TL-21a)1
9-2 Optinal Accessories
・Clip adapter CL-14 (Red, Black 1set) ・Carrying case C-SP
・HV probe HV-20
[Specifications]
Max. rated input value : DC 30 kV Accuracy : ±20 %
Internal resistance : 480 MΩ
Dimension :φ18273 mm
(
Barrier:φ40Test pin:φ3.5 mm7)
Mass: 160 g (Without cord)
Cord length : Approx.900 mm