DRAWING No SP21 18-1805 2040 2040
Function full scale value Accuracy Remaks

9-3 Measurement Range and Accuracy
 Accuracyassurance range 23 ℃±2 ℃ 4575 RH max.
 No condensaition
 Attitude Horizontal(±5 °)
 ACV accuracy in the case of sine wave AC.




Battery
Check
Capacity
F
0.3
3/12/30/120/600
6/30
12/30/120/300/600
2 k/20 k/2 M
1 10 1 k
2.0 V
±3 against
full scale


Input impedance 5 kΩ
Input impedance 20 kΩ/V
Input impedance 20 kΩ/V
Input impedance 9 kΩ/V
Frequency40 Hz100 kHz
with in ±3 % f.s.(AC 12 V
range)
Voltage drop 0.3 V
Not including the
resistance of the fuse
Center value 20 Ω
Max. Value 2 kΩ
Release voltage 3 V
Load resistance 20 Ω
Poiter indication of the
maximum move by
charged current in the
capacitor.
 Spesifications and external appearance of the product described
above may be revised for modification without prior notice.
±5 against
full scale
±3 against
full scale
±3 against
full scale
±3 of arc
60 /30 m/0.3

Release voltage 3 V

500
Do not use the tester near places where strong electromagnetic
waves and trance are generated or strong electrical voltages are
generated.

Table of Contents