- 49 -
Input signal   NTSC  colour bar
Input mode  (Video)
Input image  Natural
1. Enter the service mode.
2.  Select group/item  no.  "260 -  0",  and the data value  
changed  from  “0”  to “1”  ,  then  automatic adjustment 
will be done after about 30 sec. 
3.  After this  adjustment  completed, “
OK” will appear on 
screen. 
Conrm the color bar each color has changed into the 
black after adjustment. 
Note ;
 Include the white 100%, black 0% red 100%, blue 100% 
and green 100%  in the color bar of the input signal. 
Electrical Adjustments
Input signal   16-step gray scale signal (XGA1)
Input mode  PC Analog
Input image  Natural
G-sync off
1. Enter the service mode.
2.  Select group/item  no.  "260 -  0",  and the data value  
changed  from  “0”  to “1”  ,  then  automatic adjustment 
will be done after about 30 sec. 
3.  After this  adjustment  completed, “
OK” will appear on 
screen. 
3. Auto Calibration adjustment [PC]
4. Auto Calibration adjustment [Composite] NTSC
Input signal   480i (Y, Cb, Cr)  colour bar
Input mode  (Component1)
Input image  Natural
1. Enter the service mode.
2.  Select group/item  no.  "260 -  0",  and the data value  
changed  from  “0”  to “1”  ,  then  automatic adjustment 
will be done after about 30 sec. 
3.  After this  adjustment  completed, “
OK” will appear on 
screen. 
Conrm the color bar each color has changed into the 
black after adjustment.
Note ;
 Include the white 100%, black 0% red 100%, blue 100%  
and green 100%  in the color bar of the input signal. 
5. Auto Calibration adjustment [Component] 480i
Equipment   Digital voltmeter
1. Enter the service mode.
2. Change data values of each test points to adjust the fan 
minimum output voltage.
Item no.   Fan Location   Test Point  Adjustment value
250 - 8  FN901   FAN1  3.5 ±0.05Vdc
250 - 9  FN902   FAN2  3.5 ±0.05Vdc
250 - 10  FN903   FAN3  3.5 ±0.05Vdc
250 - 11  FN904   FAN4  3.5 ±0.05Vdc
  GND  TE35B 
Note:
The location of each fan is refer to the parts list. 
FN905  is non adjustment.
1. Fan minimum voltage adjustment
Equipment   Digital voltmeter
1. Enter the service mode.
2. Change data values of each test points to adjust the fan 
minimum output voltage.
Item no.   Fan Location   Test Point  Adjustment value
250 - 12  FN901   FAN1    13.8 ±0.05Vdc
250 - 13  FN902   FAN2  13.8 ±0.05Vdc
250 - 14  FN903   FAN3  13.8 ±0.05Vdc
250 - 15  FN904   FAN4  13.8 ±0.05Vdc
  GND  TE35B 
Note:
The location of each fan is refer to the parts list. 
FN905  is non adjustment.
2. Fan maximum voltage adjustment
+0
-0.05Vdc
+0
-0.05Vdc
+0
-0.05Vdc
+0
-0.05Vdc