28 MICRA SATEL
can be programmed. Acknowledgement of the CLIP test transmission receipt will make the
module stop repeating such a transmission (e.g. if the test transmission is programmed to
be repeated 5 times, but it is already received at the first attempt, the module will not send
the other 4 transmissions).
-> SMS – if the "Acknowledgement" field is selected and receiving the CLIP test transmission
is not acknowledged, the module may send a "CLIP failed" SMS message to the selected
telephone number.
CLIP
CLIP starts test transmission – if this option is enabled, it is possible to send a test
transmission with the use of CLIP service. Call the module telephone number and after
hearing the dialing tone, hang up – the module will identify the telephone number of the
calling party and send a test transmission according to the preprogrammed settings.
Send SMS with module status to CLIP – if this option is enabled, it is possible to obtain
information about the module status with the use of CLIP service. Call the module
telephone number and after hearing the dialing tone, hang up – the module will identify the
telephone number of the calling party and send to that number an SMS message
containing the following information:
– module name;
– version of module software (version number and date of build);
– S0 ÷ S4 – current level of signal received by the antenna;
– P – current supply voltage value.
– Z1 ÷ Z4 – information on the status of Z1 ÷ Z4 zones:
i – digital / analog zone normal status,
I – digital zone violated,
L – voltage at analog zone has dropped below threshold L; information on voltage
value,
H – voltage at analog zone has exceeded threshold H; information on voltage value,
b – digital / analog zone blocked,
A – alarm,
a – alarm memory.
– TMP – information on status of TMP zone:
i – zone normal status,
I – zone violated,
b – zone blocked,
A – alarm,
a – alarm memory.
– Z6 ÷ Z13 – information on the status of Z6 ÷ Z13 zones:
i – zone normal status,
I – zone violated,
b – zone blocked,
A – alarm,
a – alarm memory,
T – zone tamper.
– information on the status of module working in the alarm device mode:
ARM – armed,
DISARM – disarmed.
– AC – information on the module voltage status:
i – AC voltage presence,