EasyManua.ls Logo

SATO GY412 - Reverse Eject Motion

SATO GY412
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 8: Appendix
Page 8-14 GY412 Operator Manual
8.6 REVERSE EJECT MOTION
The GY412 printer has the reverse eject function to achieve better operability. Pressing the [] key in
OFFLINE state will execute the reverse eject motion.
The head assembly will be lifted up and the label will be fed backward in the reverse eject motion. When the
label is off the platen completely, “no label error” will occur and the printer stops.
Notes:
If a sensor malfunction occurs during the reverse eject motion or if the printer cannot detect the top of
label, the printer will feed the label for 650mm and generate a sensor error.
Upper head
Paper end sensor
Standby
Lower head
Close the lower head
Up
Down
ིཱ཰
Up
Down
Up
Down
Up
Down
཰
Feed the label backward
No label error occurs because the label
is not at the sensor position.
In this case, the platen is lifted up for
loading the label.
ིཱ཰
Start of reverse eject motion

Table of Contents