Section 8: Appendix
GY412 Operator Manual Page 8-7
8.2 OFFSET POSITION ADJUSTMENT
8.2.1 Adjustment of Base Position for Printing
Label stop position (print position) is adjustable within the range of +7.5mm to -7.5mm due to the above
settings on the LCD screen.
Note: The above base position for printing will be the stop position when the GAP sensor is selected.
Adjustments
LCD setting for F-PITCH
POSITION
Operation panel
PITCH POSITION
* See [TEST PRINT] in
Factory Mode of the
Configuration and Opera-
tion section.
+3.75mm to -3.75mm
LCD setting for PITCH
POSITION Operation panel
Operation panel
PITCH POSITION
+3.75mm to -3.75mm
Base position for printing (head position)
No adjustment
“+” adjustment
-7.5mm
+7.5mm
“-“ adjustment
Label feed direction