Mirror Image
Command Structure <ESC>RM
Example: <ESC>A103000832<ESC>RM
Placement: After label data
Default: None
Command Function To allow mirror image printing of data, such as on transparent labels
to be applied to a glass or other transparent surface.
Input to Printer
Label #1
<ESC>A
<ESC>A1<ESC>H0100<ESC>V0050<ESC>XL0ABCDEF
<ESC>
RM
<ESC>Q1<ESC>Z
Printer Output
Special Notes 1. The <ESC>A1 Media defines the area to be mirrored.
2. This command can be used with the <ESC>% Rotate Fixed Base
Reference Point command. Please note that the reference point
rotation is dependent upon the location of the <ESC>% command
in the data stream
3. This command should not be specified more than once in any
single job.
4. This command cannot be used with commands requiring
re-editing of the print area, such as Sequential Numbering, Real
time clock or Copy Image Area.
Page5-54PN9001073RevCSATO“Se”PrintEngines