Expanded MemoryFunction
Format/Field Recall
Command Structure <ESC>YR,aa <ESC>/D,bb,cc...c
aa = Format number to be recalled (01-99)
bb = Field number to be recalled (01-99)
cc...c= Data to be placed in recalled field.
Example: <ESC>YR,01<ESC>/D,01,99
Placement: Immediately after <ESC>CC Memory Area Select
command
Default: None
Command Function To recall a field from a stored format and place new data in the field.
Printer Input
<ESC>A
<ESC>CC1
<ESC>
YR,02
<ESC>
/D,01,TWO FIELDS OF
<ESC>
/D,02,VARIABLE DATA
<ESC>Q1<ESC>Z
Printer Output
Special Notes 1. This command requires the Expanded Memory option. See your
SATO representative for details.
2. Only one format can be recalled at a time. However, multiple fields
may be recalled from the same format.
3. The number of data characters contained in the “cc...c” field
cannot exceed the value designated in the <ESC>/N Field Store
command. If it does, the data will be truncated to fit the field length
defined in the Field Store Command.
SATO“Se”PrintEnginesPN9001073RevCPage5-85
Section 5. Programming Reference