Interface Status (SOH + IG)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII IG
causes the printer to return a 1 byte Interface Status Word bounded by an STX-ETX
pair that reports the type of interface connection currently set in the printer.
BYTE
NUMBER
VALUE DESCRIPTION
10
1
2
3
IEEE 1284 Parallel
Serial RS232
Local Area Network
Universal Serial Bus
Serial Interface Settings (SOH + H2)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII H2
causes the printer to return a 5 byte Serial IF Status Word bounded by an STX-ETX
pair that reports the current operating parameters of the Serial RS232 Interface.
BYTE
NUMBER
VALUE DESCRIPTION
10
1
2
3
9600 BPS
19200 BPS
38400 BPS
57600 BPS
20
1
3
No Parity
Odd Parity
Even Parity
30
1
1 Stop Bit
2 Stop Bits
40
1
2
3
4
Single Item Buffer with Ready/Busy Flow Control
Multi-Item Buffer with Ready/Busy Flow Control
X-ON/X-OFF Flow Control
Status 4 Bi-Comm
Status 3 Bi-Comm
SATO“Se”PrintEnginesPN9001073RevCPage6-17
Section 6. Interface Specifications