Measurement Range can be selected by Auto Range or Manual Range..
Auto Ranging Scales: : 5V, 50V, 500V, 600V (4 ranges)
Manual Ranging Scales: : 50㎷
, 500㎷, 5V, 50V, 500V, 600V (6 ranges)
The measured Voltage value is displayed on the main display with polarity indication.
Ba
r-Graph changes depending on the level of the value from the “0” point.
The Sub Menu allows for: Min/Max, Relative, measurements.
AC+DC Voltage Measurement
The Meter measures the combined value AC+DC Voltage measurement, Measurement value
displayed is the (Absolute Value). Bar-Graph will display in the Positive (+) direction only.
Press the main function key.
Next press the Menu key and select “VAC+DC" among VAC, VDC, VAC+DC
Insert Black (-)Test Lead to COM input terminal and insert Red (+)Test Lead into “V” input
terminal
Start measurement